Condition monitor CM-1001 is used for minimizing damage of rotating machinery by continuously monitoring health condition of the rotating machinery. For instance, detecting broken cutting tool of machine tool, diagnosis of pump-motor trouble are effective.
CM-1001 including data logger function. Then it can record machine condition in microSD form just before the trouble. This function will be very useful to prevent recurrence.
Model | CM-1001 |
---|---|
Measuring range | |
Number of input channel | 1 |
Applicable vibration sensor | Piezoelectric accelerometer |
option: Electro-dynamic vibration sensor (max. ±5V, input impedance 100kΩ) | |
option: Optical position detector (max. ±5V, input impedance 100kΩ) | |
Measuring and frequency range | Acceleration: 0.1 to 40m/s² 10Hz to 20kHz ±3dB Velocity: 0.1 to 200mm/s 10Hz to 1kHz ±1.5dB (based on JIS B0907-1989) Displacement: 1.0 to 5000μm 10Hz to 1kHz±1.5dB |
Measuring mode | Acceleration: 0-peak, True rms, Crest Factor Velocity: True rms Displacement: derived peak-peak Above data are indicated simultaneously and time graph is displayed. |
Analysis and Monitoring mode | |
Over-all vibration monitoring | Include |
Frequency band monitoring | option |
Unbalance vibration monitoring | option |
Harmonic vibration analysis | option |
Time waveform observation function | option |
FFT analysis | N/A |
Thresholds | |
Setting range | 5 to 99.9% of Full Scale. Each item of measuring mode. |
Monitor output | |
Alarm | Output when measured value exceed set alarm level |
Trip | Output when measured value exceeded set trip level |
Power supply malfunction alarm | Output when power supply lost |
“Under monitoring” output | This signal is active during monitoring | “Operation mode” output | This signal indicates operation mode is “Remote” or “Local”. |
Output rating | Open collector output (DC30V 50mA) Contact rating for power loss: DC24V,1A or AC125V,0.3A |
External input | |
Command of start monitor | Active only at remote operation |
Reset command for alarm | Alarm output is reset and Trip output not reset |
Reset command for Trip | Trip output is reset |
Remote Local switching | Switching Remote mode and Local mode |
Command of Power On | Power on at remote mode |
Input rating | Photo Coupler input (DC12V,10mA) |
Others | |
USB Port | Data transfer to PC, Storage LCD screen image |
Data storage | Storage of measured data in microSD card. Storage LCD screen image(32GB Max.) |
Display | 3.5 inch TFT color LCD |
Operation | Dialog with touch screen |
Environment | Temperature: 10 to 30°C (without condensation) Humidity: 20 to 80% |
Power supply | AC100 to 240V ±10% 50/60Hz |
Dimension | 170 (W)x 35.5 (L)x 95 (H)mm |
Mass | 350g |
Accessories | |
Vibration sensor | Piezoelectric Accelerometer, Model:P12SC (Sensitivity: 10pC/ (m/s²) ) Fixing magnet: KM-025C (Adsorption force 100N) Connecting cable: LN-041 (2.5m) |
Rotation sensor | SFS-M1H Fixing magnet: DG1030 |