• Measurement range
    Applicable Rotors Rigid Rotor, Grinding wheel(G:1-plane, GW:2-plane)
    Balancing Speed 180min–1 to 120,000min–1
    Resolution of rotational speed display 1 min–1
    Amplitude range of synchronized vibration 0.001 to 999 µm (at 6,000min–1)
    Resolution of vibration 0.001µm
    Vibration input channel 2ch
    Measuring method Fixed-speed method
    No. of Correction plane 1 or 2, selectable
    Correction method
    Polar coordinates 1° to 360° (angle resolution: °)
    Components of unbalance vector 3 to 50
    Correction weight Add / Remove
    Vibration analysis function
    Unbalance Vibration Analysis 0.001 to 999µm (at 6,000min–1)
    Harmonic analysis 0.001 to 999µm (at 6,000min–1)
    FFT Analyzsis (option) Maximum analysis frequency: 20kHz
    Overall amplitude monitoring (Optional) Acc P、Acc RMS、Acc CF、Vel R、Disp EQP(range Acc:0.1 to 40m/s²)
    Time domain Waveform (Optional) 800 lines max.
    Others
    USB memory port N/A
    USB interface USB mini connector (transfer to PC for data and Screenshots)
    microSD card slot N/A
    Eccentricity compensation Available as standard
    Measuring range selection Automatic ranging
    No. of stored work data 10
    Graphic display 5.7" TFT color LCD (LED back light)
    Set up operation Dialog with touch screen
    Power supply AC adapter: AC 100 to 240V ±10% 50/60Hz
    Environment Temperature: 10 to 40°C, Humidity: 20 to 80%RH (Non-condensing)
    Dimension of measuring unit 385(W) × 120(D) × 255(H)mm, (integrated in attache case)
    Mass of carrying case Approx. 4.2kg (with main unit and all accessories)
    Standard accessories
    Vibration sensor P12SC Sensitivity: 10pC/(m/s²)
      fixing magnet: KM-025C (Holding force: 100N)
      sensor cable: LN-041 (2.5m straight)
    Rotation sensor SFS-M1H (with 2m cable)
      fixing magnet stand: NF2021 (Holding force: 320N)
      with manual and an adjust driver
    AC adapter UN318-0628(DC6V 2.8A)
    Circular protractor 822-0001(ø15cm)
    Manual CD-ROM, Digest booklet
    Optional
    FFT Analyzer (-F) Frequency analysis / Time domain Waveform / Overall amplitude monitoring
    Unbalance correction Balance weights arrangement for grinding wheel (8802RHG: 1-plane, 8802RHGW: 2-plane)
    Vibration input channel N/A
    Internal Printer(-P) N/A
    Additional sensor for multi-point measurement Vibration sensor:P12SC with cable:LN-041(2.5m)
    Measurement range
    Applicable Rotors Rigid Rotor, Grinding wheel(G:1-plane, GW:2-plane)
    Balancing Speed 180min–1 to 61,000min–1
    Resolution of rotational speed display 1 min–1
    Amplitude range of synchronized vibration 0.001 to 999 µm (at 6,000min–1)
    Resolution of vibration 0.001µm
    Vibration input channel 2ch
    Measuring method Fixed-speed method
    No. of Correction plane 1 or 2, selectable
    Correction method
    Polar coordinates 1° to 360° (angle resolution: °)
    Components of unbalance vector 3 to 50
    Correction weight Add / Remove
    Vibration analysis function
    Unbalance Vibration Analysis 0.001 to 999µm (at 6,000min–1)
    Harmonic analysis 0.001 to 999µm (at 6,000min–1)
    FFT Analyzsis (option) Maximum analysis frequency: 20kHz
    Overall amplitude monitoring (Optional) Acc P、Acc RMS、Acc CF、Vel R、Disp EQP(range Acc:0.1 to 40m/s²)
    Time domain Waveform (Optional) 800 lines max.
    Others
    USB memory port N/A
    USB interface USB mini connector (transfer to PC for data and Screenshots)
    microSD card slot N/A
    Eccentricity compensation Available as standard
    Measuring range selection Automatic ranging
    No. of stored work data 10
    Graphic display 5.7" TFT color LCD (LED back light)
    Set up operation Dialog with touch screen
    Power supply AC adapter: AC 100 to 240V ±10% 50/60Hz
    Environment Temperature: 10 to 40°C, Humidity: 20 to 80%RH (Non-condensing)
    Dimension of measuring unit 385(W) × 120(D) × 255(H)mm, (integrated in attache case)
    Mass of carrying case Approx. 4.2kg (with main unit and all accessories)
    Standard accessories
    Vibration sensor P12SC Sensitivity: 10pC/(m/s²)
      fixing magnet: KM-025C (Holding force: 100N)
      sensor cable: LN-041 (2.5m straight)
    Rotation sensor SFS-M1H (with 2m cable)
      fixing magnet stand: NF2021 (Holding force: 320N)
      with manual and an adjust driver
    AC adapter UN318-0628(DC6V 2.8A)
    Circular protractor 822-0001(ø15cm)
    Manual CD-ROM, Digest booklet
    Optional
    FFT Analyzer (-F) Frequency analysis / Time domain Waveform / Overall amplitude monitoring
    Unbalance correction Balance weights arrangement for grinding wheel (8802RHG: 1-plane, 8802RHGW: 2-plane)
    Vibration input channel N/A
    Internal Printer(-P) N/A
    Additional sensor for multi-point measurement Vibration sensor:P12SC with cable:LN-041(2.5m)
    Measurement range
    Applicable Rotors Rigid Rotor, Grinding wheel(G:1-plane, GW:2-plane)
    Balancing Speed 60min–1 to 61,000min–1
    Resolution of rotational speed display 1 min–1
    Amplitude range of synchronized vibration 0.001 to 999 µm (at 6,000min–1)
    Resolution of vibration 0.001µm
    Vibration input channel 2ch
    Measuring method Fixed-speed method
    No. of Correction plane 1 or 2, selectable
    Correction method
    Polar coordinates 1° to 360° (angle resolution: °)
    Components of unbalance vector 3 to 50
    Correction weight Add / Remove
    Vibration analysis function
    Unbalance Vibration Analysis 0.001 to 999µm (at 6,000min–1)
    Harmonic analysis 0.001 to 999µm (at 6,000min–1)
    FFT Analyzsis (option) Maximum analysis frequency: 20kHz
    Overall amplitude monitoring (Optional) Acc P、Acc RMS、Acc CF、Vel R、Disp EQP(range Acc:0.1 to 40m/s²)
    Time domain Waveform (Optional) 800 lines max.
    Others
    USB memory port N/A
    USB interface USB mini connector (transfer to PC for data and Screenshots)
    microSD card slot N/A
    Eccentricity compensation Available as standard
    Measuring range selection Automatic ranging
    No. of stored work data 10
    Graphic display 5.7" TFT color LCD (LED back light)
    Set up operation Dialog with touch screen
    Power supply AC adapter: AC 100 to 240V ±10% 50/60Hz
    Environment Temperature: 10 to 40°C, Humidity: 20 to 80%RH (Non-condensing)
    Dimension of measuring unit 385(W) × 120(D) × 255(H)mm, (integrated in attache case)
    Mass of carrying case Approx. 4.2kg (with main unit and all accessories)
    Standard accessories
    Vibration sensor Vibration sensor P12SC Sensitivity: 10pC/(m/s²)
      fixing magnet: KM-025C (Holding force: 100N)
      sensor cable: LN-041 (2.5m straight)
    Low-speed Displacement Sensor V10L Sensitivity: 0.5mv/µm Note:Vibration sensors for RL, RLB (type V10L) can be used only for low speed balancing. The sensors cannot be used for general vibration measurement purpose other than balancing.
      fixing magnet: MB-B (Holding force: 800N)
      sensor cable: 2.5m
    Rotation sensor SFS-M1H (with 2m cable)
      fixing magnet stand: NF2021 (Holding force: 320N)
      with manual and an adjust driver
    AC adapter UN318-0628(DC6V 2.8A)
    Circular protractor 822-0001(ø15cm)
    Manual CD-ROM, Digest booklet
    Optional
    FFT Analyzer (-F) Frequency analysis / Time domain Waveform / Overall amplitude monitoring
    Unbalance correction Balance weights arrangement for grinding wheel (8802RHG: 1-plane, 8802RHGW: 2-plane)
    Vibration input channel N/A
    Internal Printer(-P) N/A
    Additional sensor for multi-point measurement Vibration sensor:P12SC with cable:LN-041(2.5m)