Measurement range | |
---|---|
Applicable Rotors | Rigid Rotor, Grinding wheel(G:1-plane, GW:2-plane) |
Balancing Speed | 180min–1 to 120,000min–1 | Resolution of rotational speed display | 1 min–1 |
Amplitude range of synchronized vibration | 0.001 to 999 µm (at 6,000min–1) |
Resolution of vibration | 0.001µm |
Vibration input channel | 2ch |
Measuring method | Fixed-speed method |
No. of Correction plane | 1 or 2, selectable |
Correction method | |
Polar coordinates | 1° to 360° (angle resolution: °) |
Components of unbalance vector | 3 to 50 |
Correction weight | Add / Remove |
Vibration analysis function | |
Unbalance Vibration Analysis | 0.001 to 999µm (at 6,000min–1) |
Harmonic analysis | 0.001 to 999µm (at 6,000min–1) |
FFT Analyzsis (option) | Maximum analysis frequency: 20kHz |
Overall amplitude monitoring (Optional) | Acc P、Acc RMS、Acc CF、Vel R、Disp EQP(range Acc:0.1 to 40m/s²) |
Time domain Waveform (Optional) | 800 lines max. |
Others | |
USB memory port | N/A |
USB interface | USB mini connector (transfer to PC for data and Screenshots) |
microSD card slot | N/A |
Eccentricity compensation | Available as standard |
Measuring range selection | Automatic ranging |
No. of stored work data | 10 |
Graphic display | 5.7" TFT color LCD (LED back light) |
Set up operation | Dialog with touch screen |
Power supply | AC adapter: AC 100 to 240V ±10% 50/60Hz |
Environment | Temperature: 10 to 40°C, Humidity: 20 to 80%RH (Non-condensing) |
Dimension of measuring unit | 385(W) × 120(D) × 255(H)mm, (integrated in attache case) |
Mass of carrying case | Approx. 4.2kg (with main unit and all accessories) |
Standard accessories | |
Vibration sensor | P12SC Sensitivity: 10pC/(m/s²) fixing magnet: KM-025C (Holding force: 100N) sensor cable: LN-041 (2.5m straight) |
Rotation sensor | SFS-M1H (with 2m cable) fixing magnet stand: NF2021 (Holding force: 320N) with manual and an adjust driver |
AC adapter | UN318-0628(DC6V 2.8A) |
Circular protractor | 822-0001(ø15cm) |
Manual | CD-ROM, Digest booklet |
Optional | |
FFT Analyzer (-F) | Frequency analysis / Time domain Waveform / Overall amplitude monitoring |
Unbalance correction | Balance weights arrangement for grinding wheel (8802RHG: 1-plane, 8802RHGW: 2-plane) |
Vibration input channel | N/A |
Internal Printer(-P) | N/A |
Additional sensor for multi-point measurement | Vibration sensor:P12SC with cable:LN-041(2.5m) |
Measurement range | |
---|---|
Applicable Rotors | Rigid Rotor, Grinding wheel(G:1-plane, GW:2-plane) |
Balancing Speed | 180min–1 to 61,000min–1 | Resolution of rotational speed display | 1 min–1 |
Amplitude range of synchronized vibration | 0.001 to 999 µm (at 6,000min–1) |
Resolution of vibration | 0.001µm |
Vibration input channel | 2ch |
Measuring method | Fixed-speed method |
No. of Correction plane | 1 or 2, selectable |
Correction method | |
Polar coordinates | 1° to 360° (angle resolution: °) |
Components of unbalance vector | 3 to 50 |
Correction weight | Add / Remove |
Vibration analysis function | |
Unbalance Vibration Analysis | 0.001 to 999µm (at 6,000min–1) |
Harmonic analysis | 0.001 to 999µm (at 6,000min–1) |
FFT Analyzsis (option) | Maximum analysis frequency: 20kHz |
Overall amplitude monitoring (Optional) | Acc P、Acc RMS、Acc CF、Vel R、Disp EQP(range Acc:0.1 to 40m/s²) |
Time domain Waveform (Optional) | 800 lines max. |
Others | |
USB memory port | N/A |
USB interface | USB mini connector (transfer to PC for data and Screenshots) |
microSD card slot | N/A |
Eccentricity compensation | Available as standard |
Measuring range selection | Automatic ranging |
No. of stored work data | 10 |
Graphic display | 5.7" TFT color LCD (LED back light) |
Set up operation | Dialog with touch screen |
Power supply | AC adapter: AC 100 to 240V ±10% 50/60Hz |
Environment | Temperature: 10 to 40°C, Humidity: 20 to 80%RH (Non-condensing) |
Dimension of measuring unit | 385(W) × 120(D) × 255(H)mm, (integrated in attache case) |
Mass of carrying case | Approx. 4.2kg (with main unit and all accessories) |
Standard accessories | |
Vibration sensor | P12SC Sensitivity: 10pC/(m/s²) fixing magnet: KM-025C (Holding force: 100N) sensor cable: LN-041 (2.5m straight) |
Rotation sensor | SFS-M1H (with 2m cable) fixing magnet stand: NF2021 (Holding force: 320N) with manual and an adjust driver |
AC adapter | UN318-0628(DC6V 2.8A) |
Circular protractor | 822-0001(ø15cm) |
Manual | CD-ROM, Digest booklet |
Optional | |
FFT Analyzer (-F) | Frequency analysis / Time domain Waveform / Overall amplitude monitoring |
Unbalance correction | Balance weights arrangement for grinding wheel (8802RHG: 1-plane, 8802RHGW: 2-plane) |
Vibration input channel | N/A |
Internal Printer(-P) | N/A |
Additional sensor for multi-point measurement | Vibration sensor:P12SC with cable:LN-041(2.5m) |
Measurement range | |
---|---|
Applicable Rotors | Rigid Rotor, Grinding wheel(G:1-plane, GW:2-plane) |
Balancing Speed | 60min–1 to 61,000min–1 | Resolution of rotational speed display | 1 min–1 |
Amplitude range of synchronized vibration | 0.001 to 999 µm (at 6,000min–1) |
Resolution of vibration | 0.001µm |
Vibration input channel | 2ch |
Measuring method | Fixed-speed method |
No. of Correction plane | 1 or 2, selectable |
Correction method | |
Polar coordinates | 1° to 360° (angle resolution: °) |
Components of unbalance vector | 3 to 50 |
Correction weight | Add / Remove |
Vibration analysis function | |
Unbalance Vibration Analysis | 0.001 to 999µm (at 6,000min–1) |
Harmonic analysis | 0.001 to 999µm (at 6,000min–1) |
FFT Analyzsis (option) | Maximum analysis frequency: 20kHz |
Overall amplitude monitoring (Optional) | Acc P、Acc RMS、Acc CF、Vel R、Disp EQP(range Acc:0.1 to 40m/s²) |
Time domain Waveform (Optional) | 800 lines max. |
Others | |
USB memory port | N/A |
USB interface | USB mini connector (transfer to PC for data and Screenshots) |
microSD card slot | N/A |
Eccentricity compensation | Available as standard |
Measuring range selection | Automatic ranging |
No. of stored work data | 10 |
Graphic display | 5.7" TFT color LCD (LED back light) |
Set up operation | Dialog with touch screen |
Power supply | AC adapter: AC 100 to 240V ±10% 50/60Hz |
Environment | Temperature: 10 to 40°C, Humidity: 20 to 80%RH (Non-condensing) |
Dimension of measuring unit | 385(W) × 120(D) × 255(H)mm, (integrated in attache case) |
Mass of carrying case | Approx. 4.2kg (with main unit and all accessories) |
Standard accessories | |
Vibration sensor | Vibration sensor P12SC Sensitivity: 10pC/(m/s²) fixing magnet: KM-025C (Holding force: 100N) sensor cable: LN-041 (2.5m straight) |
Low-speed Displacement Sensor | V10L Sensitivity: 0.5mv/µm Note:Vibration sensors for RL, RLB (type V10L) can be used only for low speed balancing. The sensors cannot be used for general vibration measurement purpose other than balancing. fixing magnet: MB-B (Holding force: 800N) sensor cable: 2.5m |
Rotation sensor | SFS-M1H (with 2m cable) fixing magnet stand: NF2021 (Holding force: 320N) with manual and an adjust driver |
AC adapter | UN318-0628(DC6V 2.8A) |
Circular protractor | 822-0001(ø15cm) |
Manual | CD-ROM, Digest booklet |
Optional | |
FFT Analyzer (-F) | Frequency analysis / Time domain Waveform / Overall amplitude monitoring |
Unbalance correction | Balance weights arrangement for grinding wheel (8802RHG: 1-plane, 8802RHGW: 2-plane) |
Vibration input channel | N/A |
Internal Printer(-P) | N/A |
Additional sensor for multi-point measurement | Vibration sensor:P12SC with cable:LN-041(2.5m) |