SHV-5110AU is designed for automatically measuring surface waviness, indexing, drilling to correct unbalance, and unloading workpieces.
Flywheel, Pulley, Gear, etc.
Unloading is performed automatically.
From measurement to correction are performed automatically without set‐up change.
Surface waviness measurement of flywheels, shrink-fit ring gears etc. and judgment device
When hall is existing at correcting place, automatically correct another position with vector calculation.
Measured data can be transferred to PC by USB cable -optional
Model | SHV-5110AU | |
---|---|---|
Workpiece | Max. Mass | 10kg |
Max. diameter | ø320mm | |
Mechanical unit | Motor | AC servo motor, 0.75kw with brake |
Chucking adapter | Collet chuck | |
Balancing speed | 600 to 1,500min-1 | |
Bearing support system | Hard type | |
Measuring unit | Balancing plane | 1 plane |
Eccentricity correction | Included | |
Min. Achievable Unbalance | 1.0µm | |
Graphic display | 5.7" TFT color LCD with touch screen | |
Min. unbalance indication | 0.01g | |
Indication mode | Polar coordinates and (3 to 99) components of unbalance vector | |
No. of stored work data | 50 data (No limitation when use with USB memory) | |
Judgment of measured result | Judgment with set limit value | |
Data transfer | Measured data can be transferred to PC by USB cable -optional | |
Others | Power supply | 3 phase 200V ±10% |
option | Surface waviness measurement for ring gears Existing hole detection to avoid overlapped correction |
|
Dimensions | 1,061(W) × 1,310(L) × 2,154(H)mm | |
Mass | Approx. 400kg |